AQMS-400 Carbon Monoxide Analyzer(CO)
Product Summary:
FPI AQMS-400 carbon monoxide (CO) analyzer measures ambient CO concentration by employing nondispersive infrared with gas filter correlation method technology.
Quote Now
Product overview Product features Media materials
Product overview

FPI AQMS-400 carbon monoxide (CO) analyzer measures ambient CO concentration by employing nondispersive infrared with gas filter correlation method technology.


Standard Range
Max:0~1000ppm Min:0~50ppm (Selectable)
Стандартный диапазон

Max:0~1000ppm 

Min:0~50ppm (выбор)

Principle
NDIR
Принцип
NDIR (Недисперсный инфракрасный датчик)
Zero Noise
≤0.02ppm (RMS)
Нулевой шум
≤0.02ppm (RMS)
Span Noise
≤0.25ppm (RMS)
Пролетный шум
≤0.25ppm (RMS)
Lower Detectable Limit
≤0.04ppm (RMS)
Минимальный предел обнаружения
≤0.04ppm (RMS)
Display
Digital
Отображение
Цифровое
Zero Drift
<0.1ppm/24h
Дрейф нуля
<0.1ppm/24ч
Span Drift

±0.5ppm/24h

Дрейф пролета

±0.5ppm/24ч

Linearity
<1%F.S.
Линейность
<1%F.S.
Precision
<1%
Точность
<1%
Response Time
T90<60s
Время реакции
T90<60сек
Sample Flow Rate
(800±80)sccm
Расход пробы
(800±80)sccm
Data Transmission

2 channel analog (4~20) mA;

12 digital input/output;

4-way relay output;

Передача информации

2 канал аналог (4~20) мA;

12 цифровой вход/выход; 

4-х контактный релейный выход;

Communication
RS232/RS485/Ethernet
Коммуникационный интерфейс
RS232/RS485/Ethernet
Operating Temperature

US EPA Specification 20~30°C

Actual applicable:-5~55°C

Рабочая температура

US EPA Спецификация 20~30°C

Фактически применимая:-5~55°C

Operating Humidity
0~95%RH
Рабочая влажность
0~95%RH
Calibration
Multi-point calibrator
Калибровка
Многоточечный калибратор
Power Requirement

220V AC/50Hz;

110V AC/60Hz

Требуемая мощность

220V AC/50Hz;

110V AC/60Hz

Dimensions and Weight
178(H)x432(W)x597(D)mm, 28kg
Габаритные размеры и вес

178(Высота)x432(Ширина)

x597(Глубина)мм, 28кг


Product features
  • 14 meters optical path to perform high reliability;
  • Five years guarantee on GFC wheel;
  • Compliance with US EPA reference method;
  • Various outputs include ethernet and RS232;
  • User friendly interface with large screen;
  • Continuous system diagnosis with alarm;
  • Multi-tasking software allows viewing test variables while operating;
  • Temperature and pressure compensation;
  • Internal data logging with 1 min to 365 day multiple averages;


Principle
Infrared energy emitted by light source is passed through gas chamber containing the air sample, and the quantitative absorption of energy by CO in the sample cell is measured by corresponding detector.

GFC
GFC (Gas filter correlation) technology is utilized to remove interference caused by moisture and other backgrounds.

Two gas filled chambers are mounted on a rotating disc, which pass through an IR beam alternately. The measure chamber is filled with nitrogen while the reference chamber is filled with high concentration CO. IR beam then passes through the sample gas cell. The difference in absorbance is measured and provides a direct output of the gas concentration.

Data storage and analysis
Stored data are easily retrievable through the serial or ethernet port via PC client software, allowing operators to perform predictive diagnostics and enhanced data analysis by tracking parameter trends.

Media materials
Quote Now
  • Name*
  • Email*
  • PhoneNumber*
  • Country/State*
  • Message*
Captcha*
Can’t read? Try another
I agree that my data from this contact form will be collected and processed to answer my request
Copyright 2023 FPI Group All Rights Reserved.浙ICP备11039119号 Powered ByHANSUN
Request for Quotation
Do you have any questions or requests?
Fill this form to contact our experts.
Name *
Email *
Message
Submit