Mall
EN
CN VN RU

AQMS-500 Sulfur Dioxide Analyzer(SO2)

Product Summary:

FPI AQMS-500 sulfur dioxide (SO2) analyzer applies UV fluorescence technology with the photomultiplier tube (PMT) to measure SO2.

Quote Now
Product overview Product features
Product overview

FPI AQMS-500 sulfur dioxide (SO2) analyzer applies UV fluorescence technology with the photomultiplier tube (PMT) to measure SO2.

Principle
UV Fluorescence
Принцип
УФ Флуоресценция
Standard Range

Max:0~20ppm 

Min:0~100ppb

 (Selectable)

Стандартный диапазон

Max:0~20ppm 

Min:0~100ppb

 (выбор)

Zero Noise
≤0.25ppb (RMS)
Нулевой шум
≤0.25ppb (RMS)
Span Noise
≤2.5ppb (RMS)
Пролетный шум
≤2.5ppb (RMS)
Display
Digital
Отображение
Цифровое
Lower Detectable Limit
0.5ppb
Минимальный предел обнаружения
0.5ppb
Zero Drift
<1ppb/24h
Дрейф нуля
<1ppb/24ч
Span Drift

±5ppb/24h

Дрейф пролета

±5ppb/24ч

Linearity
<1%F.S.
Линейность
<1%F.S.
Precision
<1%
Точность
<1%
Response Time
T90<120s
Время реакции
T90<120сек
Sample Flow Rate
(650±65)sccm
Расход пробы
(650±65)sccm
Data Transmission

2 channel analog (4~20) mA;  

12 digital input/output; 

4-way relay output;                             

Передача информации

2 канал аналог (4~20) мA;

12 цифровой вход/выход; 

4-х контактный релейный выход;

Calibration
Multi-point calibrator
Калибровка
Многоточечный калибратор
Communication
RS232/RS485/Ethernet
Коммуникационный интерфейс
RS232/RS485/Ethernet
Operating Temperature
US EPA Specification 20~30°C, Actual applicable:0~40°C
Рабочая температура
US EPA Спецификация 20~30°C,Фактически применимая:0~40°C
Operating Humidity
0~95%RH(No:condensation)
Рабочая влажность
0~95%RH(Без конденсации)
Power Requirement

220V AC/50Hz;

110V AC/60Hz

Требуемая мощность

220V AC/50Hz;

110V AC/60Hz

Dimensions and Weight
178(H)x432(W)x609(D)mm, 22kg
Габаритные размеры и вес
178(Высота)x432(Ширина)x609(Глубина)мм, 22кг


Product features


  • Compliance with US EPA reference method;
  • Various outputs include ethernet and RS232;
  • User friendly interface with large screen;
  • Continuous system diagnosis with alarm;
  • Multi-tasking software allows viewing test variables while operating;
  • Temperature and pressure compensation;
  • Internal data logging with 1 min to 365 day multiple  averages;
  • Critical orifices provide flow stability;


Quote Now
  • Name*
  • Email*
  • PhoneNumber*
  • Country/State*
  • Message*
Captcha*
Can’t read? Try another
I agree that my data from this contact form will be collected and processed to answer my request
Copyright 2023 FPI Group All Rights Reserved.浙ICP备11039119号 Powered ByHANSUN
Request for Quotation